100-JTVF-SS (JTVF-AVB shown)
Jar top with flow control
1” (26/34) slip x slip with flow control and atmospheric vacuum breaker
Double-filtered pilot flow for maximum reliability
Balanced-pressure diaphragm for long life
Buna-N diaphragm with self-cleaning 90-mesh (200 micron) pilot water filter and captive stainless steel spring
Energy efficient, low-power encapsulated solenoid with captured plunger
Versatility
Operates in low-flow and Xerigation® applications when the RBY filter is installed upstream
Accepts latching solenoid for use with Rain Bird battery-operated controllers
External bleed to manually flush system of dirt and debris during installation and system start up
Internal bleed for spray-free manual operation
Standard flow control feature for easy system tuning
Combination reliable JTVF valve and atmospheric vacuum breaker (backflow preventer) in one unit
Incorporates all features of JTVF Series valves, plus meets I.A.P.M.O., UPC and CUPC (recognized in Canada and by the City of Los Angeles) listing specifications
Must be installed at least 6" (15,2 cm) above the highest point of water in the sprinkler pipe it serves
Consult local codes
Operating Range
Pressure: 15 to 150 PSI (1,0 to 10,3 bar)
Flow:
- 3?4" models – 1 to 20 GPM
(0,23 to 4,9 m3/h; 0,06 to 1,29 l/s)
- 1" models – 1 to 30 GPM
(0,23 to 6,82 m3/h; 0,06 to 1,89 l/s)
Operating Temperatures:
Water temperature up to 110° F (43° C);
A mbient temperature up to 125° F (52° C)
Electrical Specifications
24 VAC 50/60 Hz (cycles/sec.) solenoid
Inrush current: 0.30 A (7.2 VA) at 60 Hz
Holding current: 0.19 A (4.6 VA) at 60 Hz
Coil resistance: 42-55 Ohms
|